Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.054
Filter
1.
J. oral res. (Impresa) ; 12(1): 1-11, abr. 4, 2023. tab, ilus
Article in English | LILACS | ID: biblio-1442654

ABSTRACT

Introduction: Proximal lesions that exceed the cement enamel limit (ACE) under the gingival margin complicate impressions and the adhesive technique. Compare the magnitude of micro infiltration between conventional resin and bulk fill resin in the cervical margin relocation technique. Materials and Methods: 48 samples of human teeth re-ceived two preparations: occluso-mesial (OM) and occluso-distal (OD) under LAC; first they received the cervical margin relocation technique (RMC) with bulk fill and conventional resin; then restored with semi-direct resinous inlays. Sample analysis: immersion in 50% colloidal silver nitrate solution, 24 hours, 37°C and cut mesiodistally. Observed under a stereoscopic magnifying glass to assess dye penetration and digitally photographed, analyzed with "Image J" software. Results: Sample of 96 cavities in two groups of 48 units; control group restored with conventional resin with incremental technique and study group restored with bulk fill resin, mono-incremental technique. Probabilistic sampling. No statistically significant diffe-rences in percentage of microinfiltrated area between Filtek™ Z250™ and Filtek™ Bulk Fill™ (p-value= 0.68). Discussion: Various studies show that the presence of marginal microinfiltration exist independent of: restorative technique, consistency, adhesive mechanism and polyme-rization technique. The research carried out is no exception, observing a similar degree for both systems. Conclusions: Results allow us to conclude that conventi-onal resin and bulk fill resin did not show significant differences in microleakage percentages for the RMC technique. Outside the study framework, bulk fill resins would have comparative advantages; better behavior against light in depths greater than 2 mm, less sensitivity to the "C" factor, and less clinical time.


Introducción: Las lesiones proximales que superan el límite cemento esmalte (ACE) por debajo del margen gingival complican las impresiones y la técnica adhesiva. Comparar la magnitud de la microinfiltración entre la resina convencional y la resina de relleno en la técnica de reubicación del margen cervical. Materiales y Métodos: 48 muestras de dientes humanos recibieron dos preparaciones: ocluso-mesial (OM) y ocluso-distal (OD) bajo LAC, primero recibieron la técnica de reubicación del margen cervical (RMC) con relleno en bloque y resina convencional; luego restaurado con incrustaciones resinosas semidirectas. Análisis de la muestra: inmersión en solución de nitrato de plata coloidal al 50%, 24 horas, 37°C y corte mesiodistal. Observado bajo una lupa estereoscópica para evaluar la penetración del tinte y fotografiado digitalmente, analizado con el software "Image J". Resultados: Muestra de 96 cavidades en dos grupos de 48 unidades; grupo control restaurado con resina convencional con técnica incremental y grupo estudio restaurado con resina bulk fill, técnica mono-incremental. Muestreo probabilístico. No hubo diferencias estadísticamente significativas en el porcentaje de área microinfiltrada entre Filtek™ Z250™ y Filtek™ Bulk Fill™ (p-value = 0,68) Discusión: Diversos estudios evidencian presencia de microinfiltración marginal, independiente de técnica restauradora, consistencia, mecanismo adhesivo y técnica polimerizadora. La investigación realizada no es excepción, observándose grado similar para ambos sistemas. Conclusiones: Los resultados permiten concluir que resina convencional y resina bulk fill no presentaron diferencias significativas en porcentajes de microinfiltración para técnica RMC. Fuera del marco del estudio, resinas bulk fill tendrían ventajas comparativas; mejor comportamiento frente a la luz en profundidades superiores a 2 mm, menor sensibilidad al factor "C", y menor tiempo clínico.


Subject(s)
Humans , Resins, Synthetic , Dental Leakage , Dental Restoration, Permanent , Dental Polishing/methods
2.
J. oral res. (Impresa) ; 11(3): 1-11, jun. 30, 2022. ilus
Article in English | LILACS | ID: biblio-1427951

ABSTRACT

Objetive: To evaluate microleakage of composite resins (CR) placed over different cavitary liners after managing deep caries lesions through selective removal of soft carious tissue to soft dentin (SRCT-S). Material and Methods: Fifty four human teeth were collected for microleakage testing. Each assay comprised ICDAS 5 or ICDAS 6 carious lesions and sound teeth for controls. Sound teeth were prepared with cavities that mirrored the carious teeth cavities, which were prepared with SRCT-S. Sound and carious teeth were further randomly assigned to one of the three experimental groups: Group A: universal adhesive (UA) + CR, Group B: glass ionomer cement liner + UA + CR, and Group C: calcium hydroxide + UA+ CR. Occlusal microleakage (OM) and cervical microleakage (CM) was classified within one of 5 depth categories. ANOVA and Chi-square tests were computed (p<0.05). Results: OM and CM were similarly distributed across subgroups (p>0.05). All Group C samples with carious lesions presented some degree of microleakage. However, no statistically significant differences were observed between groups and within each group (p>0.05). Conclusion: Teeth restored with CR after SRCT-S using calcium hydroxide as a liner material seem to exhibit higher microleakage than those restored using glass ionomer or UA alone. Further clinical research is needed to deepen these findings. Clinical significance: The application of calcium hydroxide as a liner under a composite resin may reduce the longevity of a restoration after performing selective or partial removal of carious tissues. Clinicians should rethink the need of using calcium hydroxide for this application, albeit the lack of clinical evidence.


Objetivo: Evaluar la microfiltración de resinas compuestas (RC) colocadas sobre diferentes liners cavitarios después del manejo de lesiones de caries profundas mediante la remoción selectiva de tejido cariado blando hasta dentina blanda (SRCT-S). Material y Métodos: Se recolectaron 54 dientes humanos para pruebas de microfiltración. Cada ensayo comprendía lesiones cariosas ICDAS 5 o ICDAS 6 y dientes sanos para los controles. Se prepararon dientes sanos con cavidades que reflejaban las cavidades de los dientes cariados, que se prepararon con SRCT-S. Los dientes sanos y cariados se asignaron al azar a uno de los tres grupos experimentales: Grupo A: adhesivo universal (AU) + RC, Grupo B: revestimiento de cemento de ionómero de vidrio + AU + RC, y Grupo C: hidróxido de calcio + AU+ RC. La microfiltración oclusal (MO) y la microfiltración cervical (MC) se clasificaron dentro de una de las 5 categorías de profundidad. Se calcularon las pruebas ANOVA y Chi-cuadrado (p<0,05). Resultados: La MO y MC se distribuyeron de manera similar en los subgrupos (p> 0,05). Todas las muestras del Grupo C con lesiones cariosas presentaron algún grado de microfiltración. Sin embargo, no se observaron diferencias estadísticamente significativas entre grupos y dentro de cada grupo (p>0,05). Conclusión: Los dientes restaurados con RC después de SRCT-S usando hidróxido de calcio como material de revestimiento parecen exhibir una mayor microfiltración que aquellos restaurados usando ionómero de vidrio o AU solo. Se necesita más investigación clínica para profundizar estos hallazgos. Relevancia clínica: la aplicación de hidróxido de calcio como revestimiento debajo de una resina compuesta puede reducir la longevidad de una restauración después de realizar la eliminación selectiva o parcial de los tejidos cariados. Los médicos deberían reconsiderar la necesidad de usar hidróxido de calcio para esta aplicación, aunque no haya evidencia clínica.


Subject(s)
Humans , Composite Resins/chemistry , Dental Cavity Lining , Dental Leakage/classification , Glass Ionomer Cements/chemistry , Calcium Hydroxide , Resin Cements/chemistry , Dental Caries/therapy
3.
Rev. ADM ; 79(3): 146-151, mayo-jun. 2022. ilus, tab
Article in Spanish | LILACS | ID: biblio-1378372

ABSTRACT

Introducción: La finalidad del tratamiento de conductos es conseguir la máxima desinfección, conformación y sellado tridimensional. Objetivo: Comparar la capacidad del sellado apical entre dos técnicas de obturación en conductos mesiales de molares inferiores con limas fracturadas en tercio apical. Material y métodos: Se utilizaron 60 raíces mesiales de molares inferiores, instrumentados con Protaper Universal, se desgastó 4 milímetros la parte activa del instrumento y se fracturó intencionalmente en tercio apical. Se formaron dos grupos de 30 raíces mesiales (n = 30) cada uno y se utilizaron dos técnicas de obturación: grupo 1: condensación lateral clásica y grupo 2: Obtura II. Las muestras se sumergieron en tubos de ensayo y en su interior contenían 5 mL de tinta china, se diafanizaron y observaron con un microscopio estereoscópico (LEICA, EZ4D) a 35x para medir la penetración de tinta china dentro del conducto radicular. Resultados: Se encontró una mayor microfiltración apical con suficiente evidencia estadística en el grupo de Obtura II comparado con el grupo de condensación lateral clásica (p < 0.002). Conclusiones: Ambos grupos presentaron microfiltración apical; sin embargo, en el grupo que se utilizó el sistema de obturación termoplastificada Obtura II se detectó mayor filtración apical comparada con el grupo de condensación lateral clásica (AU)


Introduction: The purpose of root canal treatment is to achieve maximum disinfection, shaping and three-dimensional sealing. Objective: To compare the apical sealing capacity between two obturation techniques in mesial canals of mandibular molars with broken files in the apical third. Material and methods: 60 mesial roots of lower molars were used, instrumented with Protaper Universal, the active part of the instrument was worn by 4 millimeters and it was intentionally broken in the apical third. Two groups of 30 mesial roots (n = 30) each were formed and two filling techniques were used: group 1: classic lateral condensation and group 2: Obtura II. The samples were immersed in test tubes and contained 5 mL of Chinese ink inside, they were clear and observed with a stereomicroscope (LEICA, EZ4D) at 35x to measure the penetration of Chinese ink into the root canal. Results: A higher apical microfiltration with sufficient statistical evidence was found in the Obtura II group compared to the classic lateral condensation group (p < 0.002). Conclusions: Both groups presented apical microfiltration, however, in the group that used the Obtura II thermoplastic obturation system, greater apical filtration was detected compared to the classic lateral condensation group (AU)


Subject(s)
Root Canal Obturation/methods , Dental High-Speed Equipment/adverse effects , Dental Leakage , In Vitro Techniques , Cross-Sectional Studies , Dental Restoration Failure , Dental Pulp Cavity/anatomy & histology , Molar
4.
Braz. dent. sci ; 25(2): 1-11, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1367332

ABSTRACT

Objective: To comparatively evaluate the effect of resin infiltration, bleaching and bleaching followed by resin infiltration on the surface roughness and microhardness of human enamel with induced white spot lesions (WSLs) and their resistance to acidic challenge. Material and Methods: Sixty human specimens were randomly divided into three groups (n=20) according to the treatment modality applied; group I Icon® resin infiltration, group II bleaching and group III bleaching followed by Icon® resin infiltration. For each treatment modality, 10 specimens were tested for surface roughness and another 10 for microhardness. WSLs were artificially induced in all specimens and after treatment, all specimens were subjected to acidic challenge. Surface roughness was measured by the tapping mode of the atomic force microscope (AFM) and microhardness was measured by digital Vickers hardness tester at baseline, after induction of WSLs, after treatment and after acidic challenge. Results: Groups I and III showed significant reduction in surface roughness after treatment, while group II showed significant increase. Groups I and III showed significant increase in the microhardness after treatment, while group II showed insignificant increase. The three tested groups showed significant increase in surface roughness values and significant reduction in microhardness after acidic challenge. Conclusion: Resin infiltration and bleaching followed by resin infiltration reduced the surface roughness and enhanced the microhardness of the WSLs. The three treatment modalities failed to resist acidic challenge resulting in increasing surface roughness and reducing microhardness. (AU)


Objetivo: Avaliar comparativamente o efeito do infiltrante resinoso, clareamento e clareamento seguido de infiltração resinosa sobre a rugosidade e microdureza superficial do esmalte humano com lesões de manchas brancas induzidas (WSLs) e sua resistência ao desafio erosivo. Material e Métodos: Sessenta espécimes humanos foram divididos aleatoriamente em três grupos (n = 20) de acordo com a modalidade de tratamento aplicada; grupo I infiltrante resinoso Icon®, grupo II clareamento e grupo III clareamento seguido de infiltração resinosa Icon®. Para cada modalidade de tratamento, 10 corpos-de-prova foram testados para rugosidade superficial e outros 10 para microdureza. WSLs foram artificialmente induzidos em todas as amostras e, após o tratamento, todas as amostras foram submetidas ao desafio erosivo. A rugosidade de superfície foi medida por microscopia de força atômica em modo de contato intermitente (AFM) e a microdureza Vickers foi medida inicialmente, após a indução de WSLs, após o tratamento e após o desafio ácido. Resultados: Os grupos I e III apresentaram redução significativa da rugosidade superficial após o tratamento, enquanto o grupo II apresentou aumento significativo. Os grupos I e III apresentaram aumento significativo na microdureza após o tratamento, enquanto o grupo II apresentou aumento insignificante. Os três grupos testados mostraram aumento significativo nos valores de rugosidade superficial e redução significativa na microdureza após o desafio erosivo. Conclusão: O infiltrante resinoso e o clareamento seguido de infiltração resinosa reduziram a rugosidade de superfície e aumentaram a microdureza dos WSLs. As três modalidades de tratamento falharam em resistir ao desafio erosivo, resultando em aumento da rugosidade de superfície e redução da microdureza.(AU)


Subject(s)
Humans , Tooth Bleaching , Dental Caries , Dental Enamel , Dental Leakage
5.
Braz. dent. sci ; 25(1): 1-8, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1361503

ABSTRACT

Objective: To compare the effectiveness of local and topical anesthesia during gingival retraction in prepared abutment teeth. Material and Methods: 72 patients desiring full mouth rehabilitation or bilateral fixed partial denture in the same arch were selected based on the inclusion criteria framed and were randomly allocated into Groups A and B of 36 each. Patients in Group A received gingival retraction with topical anesthesia and Group B received gingival retraction with infiltration anesthesia. All the patients were tested for pain, discomfort and bleeding during gingival retraction. Results: There was no significant difference in pain, discomfort and gingival bleeding (P >.05) during gingival retraction using topical and local anesthetic agents. Conclusion: Topical anesthesia was equally effective as infiltration anesthesia in managing the pain, discomfort and bleeding during gingival retraction by cord packing in prepared abutment teeth. (AU)


Objetivo: Comparar a eficácia da anestesia local e tópica durante a retração gengival previa a moldagem em dentes pilares preparados. Material e Métodos: Foram selecionados 72 pacientes indicados para reabilitação bucal total ou prótese parcial fixa bilateral na mesma arcada com base nos critérios de inclusão formulados e alocados aleatoriamente nos Grupos A e B com 36 pacientes cada. Os pacientes do Grupo A receberam retração gengival com anestesia tópica e no Grupo B receberam retração gengival com anestesia infiltrativa. Todos os pacientes foram testados para dor, desconforto e sangramento durante o procedimento. Resultados: Não houve diferença significativa na dor, desconforto e sangramento gengival (P>. 05) durante a retração gengival com anestésicos tópicos e locais. Conclusão: A anestesia tópica foi tão eficaz quanto a anestesia de infiltração no controle da dor, desconforto e sangramento durante a retração gengival com fio retrator gengival em dentes pilares preparados.(AU)


Subject(s)
Humans , Pain , Dental Leakage , Gingival Retraction Techniques , Anesthetics, Local
6.
Article in English | LILACS, BBO | ID: biblio-1422278

ABSTRACT

Abstract Objective: To evaluate the microleakage at the junction between amalgam-composite resin restorations using different bonding systems. Material and Methods: In this in-vitro study, standard class II cavities were prepared on 40 human maxillary premolars. The axial and gingival floor depths of the cavities were 2 mm and 1 mm below (cementoenamel junction), respectively. The samples were divided into 4 groups (n = 10). In all groups, a layer of 1-mm thick amalgam was used as a coating for the initial part of the gingival floor. In group 1, no bonding system was used for amalgam restoration. In group 2, G-Premio Bond was applied. G-Premio bond + alloy primer and single bond + alloy primer were used in group 3 and group 4, respectively. The rest of the cavities in all groups were then repaired using FiltekZ250 composite. The samples were thermocycled at 500 rpm and immersed in 1% methylene blue solution for 24 hours to allow dye penetration. Once cut, the samples were placed under a stereomicroscope (40X) to determine the microleakage rate. Data analysis was carried out using post-hoc and Chi-square tests (p<0.05). Results: The highest and lowest microleakage rate was related to groups 1 and 3, respectively. There was a significant difference between groups (1,2) and (1,3), and (1,4), and groups (2,3) (p<0.05). Conclusion: The use of alloy primer and bonding could reduce the microleakage between the two restorations (AU).


Subject(s)
Humans , Dentin-Bonding Agents , Composite Resins , Dental Leakage , Dental Restoration, Permanent , In Vitro Techniques/methods , Chi-Square Distribution , Dental Bonding
7.
Braz. j. oral sci ; 20: e210525, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1253928

ABSTRACT

Aim: Recent reports indicate that deproteinization of acid-etched dentin surface can extend penetration depth of adhesive agents. The main goal of the present research was to investigate the deproteinization effect of Nd:YAG and diode 940 lasers on acid-etched dentin and microleakage grade in class V composite restorations. Methods: 36 extracted human premolar teeth were selected to make standard buccal and lingual class V cavities. These samples were randomly split into three sub-groups: 1.Control group, in which composite was applied for restoration after etch and bonding process without deproteinization; 2.Nd:YAG laser group, in which the teeth were deproteinized with Nd:YAG laser after etching and painting internal surfaces of cavities with Van Geison stain and then composite restorations applied just as control group; 3.Diode laser group, in which the process was similar to Nd:YAG laser group, but instead, diode 940 laser was irradiated. The teeth were bisected into two equal longitudinal buccal and lingual halves. Marginal microleakage of samples was scored by using a stereomicroscope. Kruskal- Wallis, Mann-Whitney U and Fisher's statistical tests were employed for analysis of the obtained data. Results: A significant reduction in marginal microleakage was observed for both groups treated with laser (Nd:YAG and diode 940)compared to control (p=0.001 & p=0.047). There was no significant difference in marginal microleakage between Nd:YAG laser and diode 940groups (P = 0.333). Conclusion: Nd:YAG and diode 940 laser deproteinization of acid-etched dentin decreased the marginal microleakage of in-vitro class V resin composite restorations


Subject(s)
Humans , Acid Etching, Dental , Dentin-Bonding Agents , Dental Leakage , Lasers
8.
Braz. j. oral sci ; 20: e213981, jan.-dez. 2021. ilus
Article in English | BBO, LILACS | ID: biblio-1254747

ABSTRACT

Aim: To compare the microleakage of Cention N, a subgroup of composite resins with a resin-modified glass ionomer (RMGI) and a composite resin. Methods: Class V cavities were prepared on the buccal and lingual surfaces of 46 extracted human molars. The teeth were randomly assigned to four groups. Group A: Tetric N-Bond etch-and-rinse adhesive and Tetric N-Ceram nanohybrid composite resin, group B: Cention N without adhesive, group C: Cention N with adhesive, and group D: Fuji II LC RMGI. The teeth were thermocycled between 5°-55°C (×10,000). The teeth were coated with two layers of nail vanish except for 1 mm around the restoration margins, and immersed in 2% methylene blue (37°C, 24 h) before buccolingual sectioning to evaluate dye penetration under a stereomicroscope (×20). The data were analyzed by the Kruskal-Wallis and Wilcoxon tests (α=0.05). Results: Type of material and restoration margin had significant effects on the microleakage (p<0.05). Dentin margins showed a higher leakage score in all groups. Cention N and RMGI groups showed significant differences at the enamel margin (p=0.025, p=0.011), and for the latter group the scores were higher. No significant difference was found at the dentin margins between the materials except between Cention N with adhesive and RMGI (p=0.031). Conclusion: Microleakage was evident in all three restorative materials. Cention N groups showed similar microleakage scores to the composite resin and displayed lower microleakage scores compared with RMGI


Subject(s)
Composite Resins , Dental Leakage , Glass Ionomer Cements , Molar, Third
9.
Rev. Asoc. Odontol. Argent ; 109(1): 9-19, ene.-abr. 2021. ilus, tab
Article in Spanish | LILACS | ID: biblio-1255416

ABSTRACT

Objetivo: Estimar y comparar la eficacia de diferentes técnicas de obturación para impedir el flujo de colorante a través de los conductos laterales. Materiales y métodos: Se emplearon 50 premolares inferiores extraídos y conservados en formol neutro al 5% hasta el momento de su uso, a los cuales se les realizaron conductos laterales artificiales. Una vez instrumentados los conductos principales, los dientes fueron divididos al azar en 5 grupos (n=10) para ser obturados con cuatro técnicas distintas: A) System B + inyección de gutapercha termoplástica del sistema Elements, Extruder; B) obturadores de Thermafil, ProTaper Universal; C) técnica híbrida y D) obturación con inyección de gutapercha termoplástica del sistema Elements, Extruder. Inmersos en tinta china y diafanizadas las raíces, se evaluó la longitud de penetración de la tinta en los conductos laterales. Se empleó el análisis de la varianza para detectar diferencias significativas (P<0,05) entre los niveles medios de penetración del colorante según las técnicas de obturación y las zonas del diente, y se efectuaron pruebas de rango múltiple (HSD de Tukey) para realizar comparaciones dos a dos, manteniendo fija la tasa de error por familia. Resultados: A la técnica B le correspondió el valor medio más bajo (30,63%) de penetración de tinta china. Los valores medios más elevados (54,52% y 51,74%) correspondieron a las técnicas A y C, respectivamente. Conclusión: Ninguna de las técnicas de obturación del conducto radicular empleadas ha sido capaz de impedir la filtración del colorante en los conductos laterales (AU)


Aim: To estimate and compare the different obturation techniques to avoid the flow of colorant through lateral canals. Materials and methods: 50 extracted lower premolars preserved in 5% neutral formol until the moment of use, had artificial lateral canals made. Once canals were instrumented, the teeth were randomly divided into 5 groups (n=10) to be filled with four different techniques: A) System B + injection of thermoplastic gutta-percha, Elements system, Extruder; B) Thermafil, ProTaper Universal obturators; C) hybrid technique, and D) injection of thermoplastic gutta-percha, Elements system, Extruder. Having immersed the premolars in India ink and diaphanized the roots, the penetration length of the India ink inside the canals was assessed. Analysis of variance was used to detect significant differences (P<0.05) between the mean levels of dye penetration according to the filling techniques and tooth areas, and multiple range tests (Tukey's HSD) were performed for two-to-two comparisons, keeping the error rate per family fixed. Results: Technique B had the lowest mean value (30.63%) of penetration. The highest mean values (54.52% and 51.74%) corresponded to techniques A and C, respectively. Conclusion: No obturation technique of the root canal used was able to avoid filtration of colourant in the lateral canals (AU)


Subject(s)
Humans , Root Canal Obturation , Dental Leakage/diagnosis , Gutta-Percha , Root Canal Filling Materials/chemistry , Bicuspid/anatomy & histology , Transillumination/methods , Dental Pulp Cavity/anatomy & histology
10.
J. Health Biol. Sci. (Online) ; 9(1): 1-7, 2021. tab
Article in English | LILACS | ID: biblio-1362963

ABSTRACT

Objective: When provisional acrylic crowns are used for a long time, they become more susceptible to marginal leakage by cariogenic bacteria. The objectives of this pilot clinical study were to compare cement based on zinc oxide-eugenol and calcium hydroxide by contamination with Streptococcus mutans, and calculate the sample size for the continuation of this study. Methods: Individuals receiving provisional crowns and following inclusion/exclusion criteria, were randomly distributed into 2 groups: zinc oxide-eugenol (n=8); calcium hydroxide (n=9). The temporary crowns were made by a blind researcher and cemented by another. Patients were also blinded by the cement used inside their crowns. After 2 months, a cement sample from the crowns' peripheral inner face was collected, placed in a tube containing 1 mL of sterile saline, serially diluted, plated on Mitis Salivarius Bacitracin agar, and incubated for 48 hours. Colony-forming units (CFU/mL) were counted. A statistical power analysis was performed to calculate sample size (1-ß=80%) and the Mann Whitney test to compare both cements (α=0.05). Results: Both cements were contaminated with S. mutans, with an average of 166.6 x 102 CFU/mL for calcium hydroxide and 435.3 x 102 CFU/mL for zinc oxide-eugenol, with no significant difference (p=0.311). The sample size calculated for this study was 36 per group. Conclusion: This pilot study suggests that there is important contamination inside provisional crowns used for two months, independent of the cement. The continuation of this study is needed, with a bigger sample size, to enable a comparison between the cements.


Objetivo: Quando coroas dentais provisórias são utilizadas por um longo período, elas se tornam susceptíveis à infiltração marginal por bactérias cariogênicas. O objetivo deste estudo clínico piloto foi comparar os cimentos a base de óxido de zinco e eugenol e hidróxido de cálcio pela contaminação com Streptococcus mutans e calcular o tamanho amostral para continuação deste estudo. Métodos: Indivíduos recebendo coroas provisórias e seguindo critérios de inclusão/exclusão, foram distribuídos aleatoriamente em dois grupos: óxido de zinco e eugenol (n=8); hidróxido de cálcio (n=9). As coroas provisórias foram feitas por um pesquisador cego e cimentadas por outro. Os pacientes também foram cegos quanto ao cimento utilizado dentro de suas coroas. Depois de 2 meses, amostras de cimentos foram coletadas da face interna periférica das coroas, colocadas em um tubo contendo 1 mL de solução salina estéril, diluídas de forma seriada, plaqueadas em ágar Mitis Salivarius Bacitracina e incubadas por 48 horas. Unidades formadoras de colônias (UFC/mL) foram contadas. Um teste de poder estatístico foi realizado para calcular o tamanho amostral (1-ß=80%) e o teste de Mann Whitney para comparar os dois cimentos (α=0.05). Resultados: Os dois cimentos foram contaminados com S. mutans, com uma média de 166.6 x 102 UFC/mL para o hidróxido de cálcio e 435.3 x 102 UFC/mL para o óxido de zinco e eugenol, com nenhuma diferença significativa (p=0.311). O cálculo amostral para este estudo foi 36 indivíduos por grupo. Conclusão: Este estudo piloto sugere que existe importante contaminação dentro de coroas provisórias utilizadas por 2 meses, independente do cimento. A continuação deste estudo é necessária, com maior tamanho amostral, para possibilitar a comparação entre os cimentos.


Subject(s)
Streptococcus mutans , Dental Leakage , Zinc Oxide-Eugenol Cement , Calcium Hydroxide , Eugenol , Dental Prosthesis , Tooth Crown , Crowns , Dental Cements , Denture, Partial, Fixed , Clinical Study
11.
Sâo José dos Campos; s.n; 2021. 81 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1359830

ABSTRACT

O objetivo deste estudo foi comparar as técnicas de microabrasão de esmalte (ME) e infiltração de resina (IR) em relação à resolução estética de lesões cariosas de mancha branca (LCMB) e avaliar a correlação entre a luminosidade das lesões quando transiluminadas e a resolução do problema (estudo 1); avaliar em um estudo "in vitro", a eficácia do clareamento dental, em amostras de dentes submetidos previamente a IR (estudo 2); avaliar a efetividade do clareamento dental 12 meses após a realização dos protocolos de mínima intervenção, em um estudo de série de casos (estudo 3). Para o estudo 1 foram selecionados 17 pacientes que foram divididos em 2 grupos: ME (N=8) e IR (N=9). Um dente de cada paciente foi fotografado sob condição normal e do mesmo dente com auxilio de dispositivo translume. Em seguida os pacientes foram submetidos às técnicas de mínima intervenção. Após 7 dias de acompanhamento, o mesmo protocolo fotográfico foi realizado. Para resolução estética, foi delimitado a área do dente em relação a área da mancha por software. Para avaliação da cor da mancha quando evidenciada, os valores de luminosidade (L*) das coordenadas L*a*b* foram avaliados antes e após a intervenção, sendo mensurados valores das áreas sadias e área da mancha mais enegrecida. Os dados de correlação foram submetidos ao teste de Person. A resolutividade dos tratamentos foi dada por um Teste t-Student e a diferença de luminosidade antes e após os tratamentos foi dado pelo teste Anova 2 fatores de medidas repetidas (p<0,05). Para o estudo 2, quarenta superfícies de esmalte bovino foram submetidas à desmineralização. Após, foram estabelecidos dois protocolos de manchamento. Vinte espécimes foram imersos em caldo de manchamento por 24 horas (Lab 1) ou 7 dias (Lab 2). Dez corpos-de-prova de cada grupo receberam a aplicação de IR. Todas as amostras foram clareadas com gel de peróxido de carbamida 15% por 14 dias (8 horas diárias). A mensuração da cor foi realizada em espectrofotômetro de refletância em três momentos: inicial, após o manchamento e após o clareamento. Os dados (CIEDE00) foram analisados pelo teste t-Student (p <0,05). Para o estudo 3, foram selecionados 4 voluntários, que tinham LCMB nos dentes anteriores superiores. Os pacientes foram divididos de forma aleatória em dois grupos, sendo estes: ME e IR na área de mancha. Para resolução estética das LCMB, foi determinada a área da mancha em relação a área do dente e a porcentagem da redução pós protocolos. Após 12 meses de acompanhamento, os pacientes receberam clareamento dental, com peróxido de carbamida 10%, durante 21 dias. Os dados do estudo 1 mostram que não houve correlação entre as áreas da mancha (normal e transiluminada) e a resolução estética das mesmas (p>0.05). Em relação a resolutividade, não houve diferença entre os tratamentos (p=0.403). O valor de Luminosidade aumentou após a realização dos procedimentos (p=0.001). Para o estudo 2, nenhuma diferença significativa foi observada no Lab 1 (p=0,560). Para o Lab 2, foram detectadas diferenças significativas (p=0,031). Uma vez que o clareamento foi mais efetivo no grupo não submetido a IR (Lab2). Os resultados do estudo 3 mostram que ambos os protocolos reduziram e/ou suavizaram as áreas das manchas. Após 12 meses de acompanhamento, a técnica de ME apresentou redução no valor da área de mancha. Por fim, o clareamento dental foi efetivo em ambos os protocolos, sem diferenças entre as técnicas. Frente as metodologias propostas, pode-se concluir que: não houve diferenças entre os tratamentos em relação a remoção ou mascaramento das LCMB; a cor das manchas quando transiluminadas não estão relacionadas a resolução estética das mesmas; "in vitro", dentes fortemente manchados, submetidos ao tratamento com RI, o produto parece se comportar como uma barreira semipermeável à penetração do peróxido. Por fim, ambas as técnicas podem ser indicadas para reduzir ou suavizar as áreas de mancha. A ME apresentou redução das áreas de mancha no período avaliado (12 meses). Clinicamente, o clareamento dental pode ser indicado para melhorar a cor dos dentes, independentemente do protocolo pré-estabelecido


The aim of this study was to compare enamel microabrasion (EM) and resin infiltration (RI) techniques in relation to the esthetic resolution of white spot carious lesions (WSL) and to evaluate the correlation between the luminosity of the lesions when transilluminated and the resolution of the problem (study 1); To evaluate in an "in vitro" study, the effectiveness of dental bleaching in samples of teeth previously submitted to RI (study 2); to evaluate the effectiveness of dental bleaching 12 months after the minimal intervention protocols were performed, in a case series study (study 3). For study 1, 17 patients were selected and divided into 2 groups: ME (N=8) and IR (N=9). One tooth from each patient was photographed under normal condition and the same tooth with the aid of a translume device. Then the patients were subjected to the minimal intervention techniques. After 7 days of follow-up, the same photographic protocol was performed. For esthetic resolution, the area of the tooth was delimited in relation to the area of the stain using software. To evaluate the color of the stain when evidenced, the luminosity values (L*) of the coordinates L*a*b* were evaluated before and after the intervention, being measured values of the healthy areas and area of the darker stain. The correlation data were submitted to Person's test. The resolution by the treatments was analyzed by Student's t-test, and the difference in luminosity before and after treatments was analyzed by 2-way repeated measures Anova (p<0.05). For study 2, forty bovine enamel surfaces were subjected to demineralization. Two staining protocols were established. Twenty specimens were immersed in staining broth for 24 hours (Lab 1) or 7 days (Lab 2). Ten specimens from each group received IR application. All specimens were bleached with 15% carbamide peroxide gel for 14 days (8 hours daily). Color measurement was performed by spectrophotometry at three periods: bselien, after staining, and after bleaching. Data (CIEDE00) were analyzed by Student's T test (p <0.05). For study 3, 4 volunteers with WSL in the maxillary teeth were selected. The patients were randomly divided into EM or RI for treating lesions. For esthetic resolution of WSL, the spot area relative to tooth area and the percentage of reduction after protocols were determined. After 12 months of follow-up, the patients received dental bleaching with 10% carbamide peroxide for 21 days. The data from study 1 show that there was no correlation between the stain areas (transilluminated or not) and the esthetic resolution (p>0.05). Regarding resolution, there was no difference between treatments (p=0.403). The Luminosity value increased after the procedures were performed (p=0.001). For study 2, no significant difference was observed in Lab 1 (p=0.560). For Lab 2, significant differences were detected (p=0.031), and whitening was more effective in the group not subjected to IR (Lab2). The results of study 3 show that both protocols reduced and/or softened the areas of the stains. After 12 months of follow-up, the EM technique showed a reduction in the stain area value. Finally, dental bleaching was effective with both protocols, with no differences between the techniques. Based on the proposed methodologies, it can be concluded that: there were no differences between the treatments regarding the removal or masking of WSL; the color of the stains when transilluminated is not related to their esthetic resolution; "in vitro", heavily stained teeth submitted to treatment with RI, the product seems to behave as a semi-permeable barrier to peroxide penetration. Finally, both techniques can be indicated to reduce or soften stained areas. The EM showed a reduction of stained areas in the evaluated period (12 months). Clinically, dental bleaching can be indicated to improve the color of teeth, regardless of the pre-established protocol


Subject(s)
Humans , Animals , Cattle , Tooth Bleaching , Enamel Microabrasion , Dental Caries , Dental Leakage , Esthetics, Dental , Spectrophotometers , Analysis of Variance , Color
12.
Rev. Ateneo Argent. Odontol ; 64(1): 77-82, 2021.
Article in Spanish | LILACS | ID: biblio-1252984

ABSTRACT

A pesar de los avances e innovaciones de los materiales dentales, la microfiltración marginal y la contracción durante la polimerización continúan siendo una de las causas principales del fracaso de los tratamientos en odontología restauradora. Un sellado marginal correcto será posible cuando las fuerzas de adhesión superen las fuerzas generadas por la contracción de polimerización y las fuerzas generadas por los cambios dimensionales térmicos posteriores a la polimerización, por lo que investigaciones previas demostraron que estas limitaciones pueden ser superadas con el uso de resinas Bulk Fill como material de relleno de cavidades extensas y profundas de dientes posteriores. Estas resinas. de relleno masivo, están recibiendo atención, principalmente porque se pueden colocar, a diferencia de las resinas convencionales, en incrementos de 4 mm sin afectar la contracción de la polimerización, la adaptación de la cavidad o el grado de conversión. El objetivo de la presente revisión bibliográfica es describir la contracción de polimerización y la consecuente filtración marginal que sufren las resinas compuestas para el sector posterior Bulk Fill con base de datos de la literatura (AU)


Despite advances and innovations in dental materials, marginal microfiltration and shrinkage during polymerization continue to be one of the main causes of treatment failure in Restorative Dentistry. A correct marginal seal will be possible when the adhesion forces exceed the forces generated by polymerization contraction and the forces generated by post-polymerization thermal dimensional changes, for which previous research has shown that these limitations can be overcome with the use of Bulk Fill resins as filling material for large and deep posterior tooth cavities, these massive filling resins are receiving attention mainly because they can be placed, unlike conventional resins, in 4 mm increments without affecting polymerization shrinkage. , cavity adaptation or degree of conversion. The objective of the present bibliographic review is to describe the polymerization contraction and consequent marginal filtration suffered by Composite Resins for the Bulk Fill posterior sector with a literature database (AU)


Subject(s)
Humans , Dental Marginal Adaptation , Composite Resins , Dental Leakage , Polymerization , Materials Testing , Dental Cavity Preparation , Dental Restoration, Permanent/instrumentation
13.
Odontoestomatol ; 22(35): 38-49, jul. 2020.
Article in Spanish | LILACS, BNUY-Odon, BNUY | ID: biblio-1103059

ABSTRACT

Objetivos. Evaluar y comparar la relación entre la resistencia de unión inmediata a esmalte y microfiltración de dos sistemas restauradores a base de resina compuesta. Métodos. 40 terceros molares se dividieron aleatoriamente en dos grupos: 20 molares restaurados utilizando el sistema Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, USA); y 20 molares restaurados con el sistema Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein). La mitad de los dientes de cada grupo se utilizaron para un ensayo de microtracción, mientras que la otra mitad fueron utilizados para un ensayo de microfiltración (n = 10). Resultados. Las medias y el desvío padrón de la resistencia de unión a microtracción fueron de 27.93 (±9.55) para Adper Single bond 2 + Filtek Z250 XT MPa y 33.12 (±8.18) MPa para Tetric N Bond + Tetric N Ceram (p = 0,049). En cuanto a los valores de microfiltración, no hubo diferencias estadísticamente significativas entre los grupos (p = 0,478). No fue observada una correlación significativa entre la resistencia de unión a la microtracción y la microfiltración (R2 = 0.0909; p = 0.196). Conclusiones. No se encontró una relación entre los valores de resistencia de unión y el grado de microfiltración.


Objectives. To evaluate and compare the relationship between enamel bond strength and microleakage of two composite based restorative systems. Methods. 40 third molars were randomly divided into two groups: 20 molars restored with the Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, USA) system and 20 with the Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein) system. "Half of the teeth" in each group were subjected to a bond strength test, while the others were subjected to the microleakage test. Results. The means and standard deviation of the bond strength resistance were 27.93 (± 9.55) MPa for Adper Single bond 2 + Filtek Z250 XT system and 33.12 (± 8.18) MPa for Tetric N Bond + Tetric N Ceram system (p = 0.049). Regarding microleakage values, there were no statistically significant differences between the groups (p = 0.478). No significant correlation was observed between microtensile bond strength and microleakage (R2 = 0.0909, p = 0.196). Conclusions. No relationship was found between adhesive bond values and degree of microleakage.


Objetivos. Avaliar e comparar a relação entre a resistência de união imediata ao esmalte e a microfiltração de dois sistemas restauradores baseados em resina composta. Métodos. 40 terceiros molares foram divididos aleatoriamente em dois grupos: 20 molares restaurados usando o sistema Adper Single bond 2 + Filtek Z250 XT (3M ESPE; ST PAUL, MN, EUA); e 20 molares restaurados com o sistema Tetric N Bond + Tetric N Ceram (Ivoclar Vivadent; Schaan, Liechtenstein). Metade dos dentes de cada grupo foi utilizada para um teste de resistência de união à microtração, enquanto a outra metade foi utilizada para um teste de microfiltração (n = 10). Resultados. As mídias e o padrão de resistência de união à microtração foram 27,93 (± 9,55) para Adper Single bond 2 + Filtek Z250 XT MPa e 33,12 (± 8,18) MPa para Tetric N Bond + Tetric N Ceram (p = 0,049). Em relação aos valores de microfiltração, não houve diferença estatisticamente significativas entre os grupos (p = 0,478). Não houve correlação significativa observada entre a resistência de união à microtração e a microfiltração (R2 = 0,0909; p = 0,196). Conclusões. Não foi encontrada relação entre os valores de resistência de união e o grau de microfiltração.


Subject(s)
Composite Resins , Dental Enamel , Dental Leakage , Microstraining
14.
Rev. cuba. estomatol ; 57(2): e1508, abr.-jun. 2020. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1126504

ABSTRACT

RESUMEN Introducción: La microfiltración coronal causada por los materiales de restauración temporal es considerada una de las causas del fracaso de los tratamientos endodónticos. A raíz de ello, en los últimos años se ha buscado crear un material de restauración temporal que sea capaz de evitar este problema. Objetivo: Comparar in vitro la microfiltración coronal de un cemento experimental y cuatro materiales de restauración temporal usados en endodoncia. Métodos: Se realizaron cavidades clase I en 90 premolares, divididos en 10 grupos (n= 9) y evaluados en dos periodos de tiempo (1 y 2 semanas). Se realizó la elaboración del cemento experimental, posteriormente se llevó a cabo el sellado coronal de las piezas dentales con el cemento experimental, Clip F (VOCO), Eugenato (MOYCO), Ketac™ Molar Easymix 3M (ESPE) y Coltosol® F. Los especímenes fueron sumergidos en tinta china (Pelikan) durante 1 y 2 semanas. Se evaluó la microfiltración en la interfase pared dentinaria-restauración temporal utilizando un esteromicroscopio (Leica Microsystems LAS EZ versión 2.0.0). La medición se realizó en milímetros en el programa LAS EZ versión 2.0.0. Resultados: Se encontró diferencias estadísticamente significativas (p < 0,05) al comparar la microfiltración coronal de los cinco materiales de restauración temporal, según el tiempo de exposición en tinta (1 y 2 semanas). Conclusiones: El cemento experimental presentó menor microfiltración que el Coltosol® F y Ketac™ Molar EasyMix 3M (ESPE); sin embargo, ninguno de los cuatro materiales fue capaz de prevenir la microfiltración en su totalidad(AU)


ABSTRACT Introduction: Coronal microleakage caused by temporary restorative materials is viewed as one of the reasons for endodontic failure. Efforts have been made in recent years to create a temporary restorative material capable of preventing that problem. Objective: Compare in vitro coronal microleakage of an "experimental cement" and four temporary restorative materials used in endodontics. Methods: Class I cavities were made in 90 premolar teeth divided into 10 groups (n= 9) and evaluated at two time periods (1 and 2 weeks). The "experimental cement" was prepared and then coronal sealing of the teeth was performed with the experimental Cement, F (VOCO), Eugenato (MOYCO), Ketac™ Molar Easymix 3M (ESPE) and Coltosol® F. The pieces were submerged in India ink (Pelikan)for 1 and 2 weeks. Microleakage was evaluated on the interface dentin wall / temporary restoration using a stereo microscope (Leica Microsystems LAS EZ version 2.0.0). Measurement was made in millimeters using the software LAS EZ version 2.0.0. Results: Statistically significant differences were found (p < 0.05) when comparing coronal microleakage in the five temporary restorative materials according to exposure time in ink (1 and 2 weeks). Conclusions: The experimental cement had less microleakage than Coltosol® F and Ketac™ Molar EasyMix 3M (ESPE). However, none of the four materials was capable of completely preventing microleakage(AU)


Subject(s)
Humans , Dental Restoration Failure , Dental Leakage/etiology , Endodontics/methods , Dental Cementum
15.
Acta odontol. latinoam ; 33(1): 27-32, June 2020. graf
Article in English | LILACS | ID: biblio-1130729

ABSTRACT

ABSTRACT The aim of this study was to assess the influence of differentpretreatmentapproaches on glass ionomer cement (GIC)bond strength (BS) to dentine. Sixty bovine incisors wereallocated into six groups according to substrate - sound orcariesaffecteddentine; and substrate pretreatmentapproach -no conditioning (control), polyacrylic acid for 10 s andphosphoric acid for 7 s. Teeth in the cariesaffecteddentinegroup were previously submitted to cariogenic pHcyclingchallenge. After dentine pretreatment,according to experi mentalgroups, polyethylene tubes were placed on flat dentinesurfaces and filled with GIC. Teeth were stored in distilledwater for 24 h at 37 °C and then submitted to microshear test(0.5 mm/min). Failure pattern analysis was performed understereomicroscope (400x). Data were analysed using twowayANOVA and Tukey's test (α=5%). Statistically significantdifferences were found for the pretreatmentapproach,regardless of substrate (p<0.001). The polyacrylic acid groupand control group had similar BS values, and were both betterthan the phosphoric acid group. In general, GIC had betterbonding performance in sound dentine than in cariesaffecteddentine. In conclusion, dentine pretreatmentwith polyacrylicacid did not improve the performance of GIC restoration onclinically relevant substrates.


RESUMO O objetivo deste estudo foi avaliar a influência de diferentesprétratamentosna resistência de união (RU) de cimentos deionômero de vidro (CIV) a dentina. Sessenta incisivos bovinosforam alocados em 6 grupos de acordo com o substrato -hígido ou cariado; e com a abordagem de prétratamento-sem condicionamento (controle), ácido poliacrílico por 10 s, eácido fosfórico por 7 s. Os dentes pertencentes aos grupos dedentina cariada foram previamente submetidos ao desafiocariogênico por meio da ciclagem de pH. Após o prétratamentoda dentina, de acordo com os grupos experimentais,tubos de polietileno foram colocados sobre superfícies planas dedentina e preenchidos com CIV. Os dentes foram armazenadosem água destilada por 24 h a 37°C e então submetidos ao testede microcisalhamento (0,5 mm/min). A análise do padrão defratura foi realizada em estereomicroscópio (400x). Os dadosobtidos foram analisados usando ANOVA de dois fatores e testede Tukey (α=5%). Diferença estatisticamente significante foiencontrada para as diferentes abordagens de prétratamento,independente do substrato (pp<0,001). Aplicação de ácidopoliacrílico resultou em valores de RU similares aos do grupocontrole. Entretanto, ambos os grupos mostraram um melhordesempenho quando comparado a aplicação de ácidofosfórico. De forma geral, CIV apresentou melho5 desempenhoadesivo em dentina sadia quando comparada a dentinacariada. Em conclusão, o prétratamentoem dentina comácido poliacrílico não melhora o desempenho das restauraçõesde CIV em substratos clinicamente relevantes.


Subject(s)
Animals , Cattle , Acrylic Resins/pharmacology , Dental Bonding/methods , Dentin/drug effects , Glass Ionomer Cements/chemistry , Materials Testing , Dental Leakage/prevention & control , Dentin/pathology , Dentin/diagnostic imaging
16.
Odontología (Ecuad.) ; 22(1): 21-35, 2020.
Article in Spanish, English, Portuguese | LILACS | ID: biblio-1050376

ABSTRACT

En implantología oral, ha sido motivo de investigación y constante evolución la interfase implante-pilar, princi-palmente desde el punto de vista biomecánico y biológico. Objetivo: Valorar el espacio o "gap" en la interfase implante-pilar en implantes de conexión hexagonal interna y externa por medio de microscopía electrónica de barrido (MEB). Materiales y Métodos: Estudio in vitro en 24 implantes (Bionnovation®) divididos en dos gru-pos (n=12): conexión hexagonal interna y externa. Para el experimento, se atornillaron pilares rectos con 30N de torque. A su vez 6 implantes por grupo se sometieron a 500000 ciclos de carga dinámica; posteriormente, se evaluó por MEB el espacio de la interfase implante pilar en 3 puntos de todas las muestras, las medias de los resultados de cada espécimen se respaldaron en tablas de Excel y se analizaron en el programa BioEstat 5.3. Resultados: Mediante test T para muestras independientes, con una significancia del 95%, se encontró una diferencia muy significativa luego de la aplicación de la carga dinámica en los implantes de hexágono ex-terno (p= 0.0002). En los implantes de hexágono interno también existió diferencia estadística (p= 0.03). Entre los implantes de hexágono externo e interno existieron diferencias muy significativas en la precisión del ajuste en la interfase implante pilar antes y después de la aplicación de las cargas dinámicas (p= <0.0001 y p= 0.0003 respectivamente). Conclusiones: Las cargas dinámicas aumentaron significativamente la discrepan-cia en la conexión implante-pilar de los implantes de hexágono externo e interno (p= < 0.05); adicionalmente, la distancia del "gap" fue mayor para los implantes de hexágono externo en contraste con los implantes de Hexágono Interno antes y después de la carga dinámica, siendo muy significativo (p= < 0.0003).


In oral implantology, the implant-pillar interface has been a subject of research and constant evolution, mainly from the biomechanical and biological point of view. Objective: To assess the gap in the implant-abutment interface in internal and external hexagonal connection implants by means of scanning electron microscopy (SEM). Materials and Methods: In vitro study in 24 implants (Bionnovation®) divided into two groups (n = 12): internal and external hexagonal connection. For the experiment, straight pillars with 30N of torque were screwed. In turn, 6 implants per group underwent 500,000 cycles of dynamic loading; Subsequently, the space of the pillar implant interface at 3 points of all samples was evaluated by MEB, the means of the results of each specimen were supported in Excel tables and analyzed in the BioEstat 5.3 program. Results: Using a T test for independent samples, with a significance of 95%, a very significant difference was found after the application of the dynamic load in the external hexagon implants (p = 0.0002). In the internal hexagon implants there was also a statistical difference (p = 0.03). Between the external and internal hexagon implants there were very significant differences in the accuracy of the adjustment in the abutment implant interface before and after the application of the dynamic loads (p = <0.0001 and p = 0.0003 respectively). Conclusions: Dynamic loads significantly increased the discrepancy in the implant-abutment connection of the external and internal hexa-gon implants (p = <0.05); additionally, the gap distance was greater for external hexagon implants in contrast to Internal Hexagon implants before and after dynamic loading, being very significant (p = <0.0003).


Na implantologia oral, a interface implante-pilar tem sido objeto de pesquisa e evolução constante, principal-mente do ponto de vista biomecânico e biológico. Objetivo: Avaliar o espaço ou "gap" na interface implan-te-pilar em implantes de conexão hexagonal interna e externa por meio de microscopia eletrônica de varre-dura (MEV). Materiais e Métodos: Estudo in vitro em 24 implantes (Bionnovation®) divididos em dois grupos (n = 12): conexão hexagonal interna e externa. Para o experimento, pilares retos com 30N de torque foram parafusados. Por sua vez, 6 implantes por grupo passaram por 500.000 ciclos de carregamento dinâmico; posteriormente, o espaço da interface do implante de pilar em 3 pontos de todas as amostras foi avaliado pelo MEV, as médias dos resultados de cada amostra foram suportadas em tabelas Excel e analisadas no programa BioEstat 5.3. Resultados: Usando um teste T para amostras independentes, com significância de 95%, foi encontrada uma diferença muito significativa após a aplicação da carga dinâmica nos implantes hexagonais externos (p = 0,0002). Nos implantes hexagonais internos também houve diferença estatística (p = 0,03). Entre os implantes hexágono externo e interno, houve diferenças muito significativas na precisão do ajuste na interface do implante de pilar antes e após a aplicação das cargas dinâmicas (p = <0,0001 ep = 0,0003, respectivamente). Conclusões: As cargas dinâmicas aumentaram significativamente a discrepância na conexão implante-pilar dos implantes hexágono externo e interno (p = <0,05); além disso, a distância do gap foi maior para os implantes hexagonais externos, em contraste com os implantes de hexágono interno antes e após o carregamento dinâmico, sendo muito significativa (p = <0,0003).


Subject(s)
Dental Implants , Prosthesis Fitting , Dental Leakage , Denture Design , Prosthesis Implantation
17.
Odontología (Ecuad.) ; 22(1): 66-81, 2020.
Article in Spanish, English, Portuguese | LILACS | ID: biblio-1050508

ABSTRACT

No se han establecido estándares para el tratamiento de cavidades cervicales no cariosas; un biomaterial adecuado permitirá buena adaptación y longevidad de la restauración. Objetivo: Determinar la microfiltración en cavidades clase V no cariosas restauradas con ionómero de vidrio y resina nanoparticulada. Materiales y métodos: Cavidades clase V realizadas en la superficie vestibular de 80 premolares sanos (1,5 mm de pro-fundidad x 3 mm de altura en sentido ocluso- gingival x 2 mm de ancho en sentido mesio-distal) se restauraron aleatoriamente con dos biomateriales (n = 40): 1) ionómero de vidrio y 2) resina de nano relleno. Después, los especímenes fueron aislados con barniz y sumergidos en azul de metileno por 24 horas. Posteriormente, las muestras se sometieron 500 ciclos de termociclado por 8 horas y 45 minutos con cambios térmicos de 37°, 72° y 75°C, cada ciclo con una duración de 17 segundos. Las muestras fueron lavadas con agua destilada y seccionadas longitudinalmente para determinar el grado de microfiltración utilizando un estereoscopio (Leica M60, Biosystems). Los datos categóricos se analizaron con el test Chi2 en SPSS 24®. Resultados: Se pudo apreciar que la filtración es significativamente menor en resina que con ionómeros de vidrio (p < 0,001). Sin embargo, ninguno de los materiales de restauración probados fue capaz de sellar los márgenes o las paredes de los dientes completamente. Conclusión: como resultado del presente experimento se determina que las restauraciones de clase V obturadas con resina de nano relleno presentan menor microfiltración marginal que las restauradas con ionómero de vidrio.


No standards have been established for the treatment of non-carious cervical cavities; a suitable biomaterial will allow good adaptation and longevity of the restoration. Objective: To determine microfiltration in non-car-ious class V cavities restored with glass ionomer and nanoparticulate resin. Materials and methods: Class V cavities made on the vestibular surface of 80 healthy premolars (1.5 mm deep x 3 mm high in the occlusion-gin-gival direction x 2 mm wide in the mesio-distal direction) were randomly restored with two biomaterials (n = 40): 1) glass ionomer and 2) nano-filled resin. Then, the specimens were isolated with varnish and immersed in methylene blue for 24 hours. Subsequently, the samples were subjected to 500 cycles of thermocycling for 8 hours and 45 minutes with thermal changes of 37°, 72° and 75° C, each cycle with a duration of 17 seconds. The samples were washed with distilled water and sectioned longitudinally to determine the degree of micro-filtration using a stereoscope (Leica M60 Biosystems). Categorical data were analyzed with the Chi2 test in SPSS 24®. Results: It was observed that filtration is significantly lower in resin than in those restored with glass ionomers (p < 0.001). However, none of the restoration materials tested were able to seal the margins or walls of the teeth completely. Conclusion: As a result of the present experiment, it is determined that class V resto-rations sealed with nano-filled resin have less marginal microfiltration than those restored with glass ionomer.


Ainda não foram estabelecidos padrões para o tratamento de cavidades cervicais não cariosas; um biomate-rial adequado permitirá boa adaptação e longevidade da restauração. Objetivo: Determinar a microfiltração em cavidades não cariosas da classe V restauradas com ionômero de vidro e resina nanoparticulada. Materi-ais e métodos: Cavidades de classe V feitas na superfície vestibular de 80 pré-molares saudáveis (1,5 mm de profundidade x 3 mm de altura na direção oclusão-gengival x 2 mm de largura na direção mesio-distal) foram restaurados aleatoriamente com dois biomateriais (n = 40): 1) ionômero de vidro e 2) resina nano-híbrida. Em seguida, as amostras foram isoladas com verniz e imersas em azul de metileno por 24 horas. Posteriormente, as amostras foram submetidas a 500 ciclos de termociclagem por 8 horas e 45 minutos com alterações tér-micas de 37°, 72° e 75° C, cada ciclo com duração de 17 segundos. As amostras foram lavadas com água destilada e seccionadas longitudinalmente para determinar o grau de microfiltração usando um estereoscópio (Leica M60, Biosystems). Os dados categóricos foram analisados com o teste Chi2 no SPSS 24®. Resul-tados: Observou-se que a filtração é significativamente menor na resina do que nos ionômeros de vidro (p <0,001). No entanto, nenhum dos materiais de restauração testados foram capazes de selar completamente as margens ou paredes dos dentes. Conclusão: como resultado do presente experimento, determina-se que restaurações de classe V seladas com resina nano-preenchida possuem menos microfiltração marginal do que aquelas restauradas com ionômero de vidro.


Subject(s)
Composite Resins , Dental Cavity Lining , Dental Leakage , Dental Marginal Adaptation , Dental Cementum
18.
Braz. oral res. (Online) ; 34: e001, 2020. tab, graf
Article in English | LILACS | ID: biblio-1055529

ABSTRACT

Abstract This study analyzed the effect of prior application of copaiba oil (CO) emulsions as a dentin cleaning substance on microleakage and microtensile adhesive strength. Twenty-five premolars and sixty-four molars were used for microleakage and microtensile assays. For the microleakage assays, specimens with standard class V cavities were divided (n = 5), according to the tested CO emulsions: CO10%X, CO10%Y, and CO10%Z, as well as chlorhexidine 2% (CHX) and distilled water (DW), as positive and negative controls, respectively. Restorations were performed using the Adper Single Bond® and/or Clearfil SE Bond® systems. Cervical, occlusal, distal and mesial sections were assessed for tracer penetration degree at the composite/tooth interface. For the microtensile assay, healthy molars were divided into sixteen groups, in which artificial caries were induced in half of the groups. Dentin surfaces were treated with CO10%X and CO10%Y, CHX and DW. Microtensile bond strength was measured by fixing each sample to the plate of a universal testing machine operated at a speed of 0.5 mm/minute until failure. Dentin treated with CO10%X showed a lower infiltration rate than dentin treated with the other CO emulsions, CHX2% and DW. According to the microtensile assay, both healthy and affected dentin treated with CO10%X and Adper Single Bond® adhesive system presented higher adhesive strength. CO emulsion, used as a dentin biomodifier, interfered positively in microleakage and improved adhesive strength after acid etching in the Adper Single Bond® adhesive system, or before applying the Clearfil SE Bond® self-etching system.


Subject(s)
Humans , Plant Oils/chemistry , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dentin/drug effects , Fabaceae/chemistry , Surface Properties , Tensile Strength , Materials Testing , Chlorhexidine/chemistry , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Composite Resins/chemistry , Resin Cements/chemistry , Dental Cements/chemistry , Dental Leakage , Dentin/chemistry , Emulsions/chemistry
19.
Braz. dent. sci ; 23(3): 1-8, 2020. ilus, graf, tab
Article in English | BBO, LILACS | ID: biblio-1116095

ABSTRACT

Objective: Proper apical seal plays an important role in the success of root canal treatment. The most common cause of failure of root canal therapy is known as the lack of adequate apical seal. The aim of this in vitro study was to compare the apical microleakage of MTA Fillapex, AH26, and Endofill sealers using dye penetration method. Material and Methods: In this in vitro study, 72 single-rooted extracted human teeth were selected. The teeth were randomly divided into three experimental groups of 20 and two positive and negative control groups of 6. The canals were prepared by step-back technique and then filled with gutta-percha and one of the sealers mentioned. In the positive control group, the canals were filled with gutta-percha without sealer, and in the negative control group, the canals were prepared but not filled. The teeth were immersed in 2% methylene blue dye for 72 hours. The teeth were then cut longitudinally and the level of dye penetration was measured under a stereomicroscope. Data were analyzed by SPSS ver. 19 software, ANOVA and Bonferroni post-hoc tests. Results: The mean level of dye penetration in the Endofill test group was significantly higher than that in the AH26 and MTA Fillapex test groups. While, the observed difference between AH26 and MTA Fillapex groups was not statistically significant (p<0.05). Conclusion: The results of this study showed that AH26 and MTA Fillapex sealers did not show any significant difference in apical seal properties. However, their sealing strength was significantly greater than Endofill sealer. (AU)


Objetivo: O selamento apical adequado desempenha um papel importante no sucesso do tratamento do canal radicular. A causa mais comum de falha da terapia endodôntica é conhecida como falta de selamento apical adequado. O objetivo deste estudo in vitro foi comparar a microinfiltração apical dos cimentos MTA Fillapex, AH26 e Endofill usando o método de penetração de corantes. Materiais e métodos: Neste estudo in vitro, 72 dentes humanos unirradiculares extraídos foram selecionados. Os dentes foram divididos aleatoriamente em três grupos experimentais de 20 e dois grupos controle, positivo e negative, de 6. Os canais foram preparados pela técnica escalonada e preenchidos com guta-percha e um dos cimentos mencionados. No grupo controle positivo, os canais foram preenchidos com guta-percha sem cimento, e no grupo controle negativo, os canais foram preparados, mas não preenchidos. Os dentes foram imersos em corante azul de metileno a 2% por 72 horas. Os dentes foram então cortados longitudinalmente e o nível de penetração do corante foi medido sob um estereomicroscópio. Os dados foram analisados pelo software SPSS ver. 19 e pelos testes ANOVA e post-hoc de Bonferroni. Resultados: O nível médio de penetração do corante no grupo de teste Endofill foi significativamente maior do que nos grupos de teste AH26 e MTA Fillapex. Enquanto, a diferença observada entre os grupos AH26 e MTA Fillapex não foi estatisticamente significante (p <0,05). Conclusão: Os resultados deste estudo mostraram que os cimentos AH26 e MTA Fillapex não apresentaram diferença significativa nas propriedades do selamento apical. No entanto, suas forças de vedação foram significativamente maiores que a do cimento Endofill. (AU)


Subject(s)
Humans , Dental Cements , Dental Leakage
20.
J. appl. oral sci ; 28: e20190499, 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1101251

ABSTRACT

Abstract Enzymatic degradation of the hybrid layer can be accelerated by the activation of dentin metalloproteinases (MMP) during the bonding procedure. MMP inhibitors may be used to contain this process. Objective To evaluate the degree of conversion (DC%), dentin bond strength (µTBS) (immediate and after 1 year of storage in water), and nanoleakage of an experimental (EXP) and a commercial (SB) adhesive system, containing different concentrations of the MMP inhibitor GM1489: 0, 1 µM, 5 µM and 10 µM. Methodology DC% was evaluated by FT-IR spectroscopy. Dentin bond strength was evaluated by µTBS test. Half of beams were submitted to the µTBS test after 24 h and the other half, after storage for 1 year. From each tooth and storage time, 2 beams were reserved for nanoleakage testing. Data were analyzed using ANOVA and Tukey's test to compare means (α=0.05). Results All adhesive systems maintained the µTBS after 1 year of storage. Groups with higher concentrations of inhibitor (5 µM and 10 µM) showed higher µTBS values than groups without inhibitor or with 1 µM. The nanoleakage values of all groups showed no increase after 1 year of storage and values were similar for SB and EXP groups, in both storage periods. The inhibitor did not affect the DC% of the EXP groups, but the SB5 and SB10 groups showed higher DC% values than those of SB0 and SB1. Conclusions The incorporation of GM1489 in the adhesive systems had no detrimental effect on DC%. The concentrations of 5 µM GM1489 for SB and 5 µM or 10 µM for EXP provided higher μTBS than groups without GM1489, in the evaluation after 1 year of storage; whereas the concentration of inhibitor did not affect adhesive systems nanoleakage.


Subject(s)
Humans , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Dental Cements/chemistry , Dentin/chemistry , Matrix Metalloproteinase Inhibitors/chemistry , Methacrylates/chemistry , Reference Values , Surface Properties , Tensile Strength , Time Factors , Materials Testing , Reproducibility of Results , Analysis of Variance , Dental Bonding/methods , Spectroscopy, Fourier Transform Infrared , Statistics, Nonparametric , Dental Leakage , Dentin/drug effects , Dental Etching/methods
SELECTION OF CITATIONS
SEARCH DETAIL